- Synchronizing Systems
- Freigabekontakt für Einschaltbefehl
- Wahl von mehreren Synchronisierstellen
- Darstellung Arbeitspunkt Generator auf P-Q Diagramm nur sinnvoll bei Generatoren / Unterwerke nicht geeignet da ein Synchroscope für mehrere Leistungsschalter eingesetzt werden kann und somit die Spannungen über externe Relaislogik und Relaiskontakte zugeschaltet werden
- Grafische Aufzeichnung bei Synchronisiervorgang
- Schwebung (Zeitdiagramm)
- Leistung (Zeitdiagramm)
- Leistung (Ortskurve – PQ Diagramm)
- Digitale Eingänge
- Text Eventrecorder für Ereignisse mit Time-stamp (GPS)
- Digitale Eingänge ON/OFF
- dU-Freigabe ON/OFF
- df-Freigabe ON/OFF
- dalpha-Freigabe ON/OFF
- DC Supply ON/OFF
- IRF (internal relay fault)
- Protection Relays
- Test Equipment
The synchronizing device SYN 99C is a low burden synchroscope. The device is available as stand alone product or as part of a complete synchronizing system. The synchronizing systems are engineered and constructed by PROTECTION according the clients needs. This synchronizing systems are used for generators and substations. The system can be designed to support up to 5 different synchronizing points.
This Synchronizing regulator supports up to 4 different parameter sets. It can be operated in automatic as in manual mode (synchrocheck). A synchroscope is implemented in the display (Phase angle with digital value from 0° to 360° and a bar display with 2° resolution). in operating mode.
Haupt-Funktion
Gerät zur Anzeige des Synchronisierungsvorganges von zwei synchronen/asynchronen Netzen.
Optionale Funktionen
Looking for optimal synchronizing Point.
Record of the real generator synchronizing.
Generator CB closing at 0° Phase shift. Well done.
Our generator protection systems are built with our own protection relays. Due to close collaboration between our system engineering and relay development departments, high system reliability is guaranteed and also very specific technical needs can be incorporated. Commissioning can be performed by our own technicians from development and engineering department.
Generator Protection in Modular Version. Each relay or each function is mounted in one module. A link od nego da void do pdf dokumentot.
- Micrografx Designer 7 -
linear from 2.5 Hz up to 65Hz
RAL 7032
- connection scheme -Generator Protection for Irak
Commission for electricity production (GCEP) Baghdad 1999
detects DC component in case of an earthfault generated by static frequency converter (SFC).
- LMD II prospect italian -
The protection relay test set is a portable, very compact multifunctional voltage and/or current source. Several constant and variable voltage and current sources are available. Incorporated frequency generator allows comfortable testing of synchronizing devices. Trip time measurement start and stop commands can be activated manually and automatically. Where requested synchroscope device SYN 99C is incorporated in the alu-box cover. This test set is applicable for testing of all types of protection and control relays.
- pgx syn english -
Also available as stand alone version (variac integrated in 50A extension).
Universal Test Set PGX30/10A.Version Commissioning Engeneer.
Testting of synchro check SYN 213.
This device together with test set PGX offers facility for CT polarity checking. Primary injection is performed by PGX (2nd Hr. output). The polarity is indicated by the systems LED on the PSX10.
- psx10 phase polarity checker -
Services
Built Systems
- Italy, Iran, Iraque….
cca 150 Start-up Protection Systems for the Gass Turbines - Italy, Rome, ENEA
(Research Institute for alternative Energy resources. Tokamak Generator Protection) - Croatia, Zagreb, Rijeka, Plomin, Senj, Rakitje……
5 x H.V. Busbar Protection System, RSX II - Africa, Khartoum
H.V. Busbar Protecion System RSX II - Macedonia, REK Bitola
220 MVA Generator protection CMC-GPX(15 years without any disturbance) - China, Panjiakou
3 x 150 MVA Hydro Generator Protection CMC-GPX - Irak, 200MVA
Generator & Step up transformer
300 MVA Thermal Power Plant Generator Protection CMC-GPX - Lybia
Synchronizing System - Italy, Taranto
3 x 200 MVA Generator Protection Rewamping (REG316) - Germany, Siemens
5 x 100Hz Generator Differential Protection (RDIM 111) - Italy, Ravenna, Polynt
Power Plant Rewamping (Protection, Measurement, Synchronizing, Excitation, Controlling)
About

Is under technical leadership of an ex BBC generator protection development chief engineer, who has started as one of the firsts the research of protection problems related to frequency variable installations (cement mills, variable frequency driven starting equipment, reversible power plants, Hydro power plants) and studies of EMV problems of protection relays.

Clients
- • ABB Energy Automation - Italy
- • ABB Process Solutions - Italy
- • ABB Utilities - Germany
- • ABB - Austria
- • Siemens - Germany
- • Siemens - Italy
- • Nuovo Pignone - Italy
- • Areva D & D - Italy
- • Areva T&D - Switerzeland
- • A2A - Italy
- • ILVA - Italy
- • Polynt - Italy
- • Cedeg - Ecuador
- • Colbun SA - Chile
- • Techint - Italy
- • Edison - Italy
- • And others